Initial commit
This commit is contained in:
@@ -0,0 +1,86 @@
|
||||
# Example power profile: solar failover
|
||||
#
|
||||
# Links one Anker SOLIX device (read-only data source) to one Shelly switch
|
||||
# channel (the actuator). Rules decide when the Shelly turns on or off.
|
||||
# The Anker device is never commanded.
|
||||
#
|
||||
# Replace the source and target filenames with your own. List them with:
|
||||
# solixauto devices
|
||||
#
|
||||
# Validate before running:
|
||||
# solixauto run solar-failover --test
|
||||
|
||||
name: solar-failover
|
||||
description: >
|
||||
Charge from the grid when the battery is low or solar cannot keep up.
|
||||
Stay off the grid whenever the sun is carrying the load.
|
||||
|
||||
enabled: true
|
||||
|
||||
poll_interval: 10s
|
||||
|
||||
source:
|
||||
profile: REPLACE-WITH-YOUR-ANKER-PROFILE.yaml
|
||||
stale_after: 300s
|
||||
on_stale: safe_state
|
||||
|
||||
target:
|
||||
profile: REPLACE-WITH-YOUR-SHELLY-PROFILE.yaml
|
||||
channel: 0
|
||||
|
||||
# The plug supplies power TO the Anker device, so every failure path should
|
||||
# end with charging enabled rather than disabled.
|
||||
safe_state: on
|
||||
|
||||
# Checked before every rule below, bypasses the rate limits, and latches once
|
||||
# tripped so nothing can turn charging off again until the battery recovers.
|
||||
safety:
|
||||
battery_floor:
|
||||
at_or_below: 20
|
||||
release_at: 40
|
||||
then: target.on
|
||||
for: 30s
|
||||
notify: true
|
||||
notify_release: true
|
||||
|
||||
notifications:
|
||||
enabled: true
|
||||
channels: [ntfy]
|
||||
title: "{profile}"
|
||||
template: >-
|
||||
{source_name} battery {battery_soc}%, solar {pv_total}W.
|
||||
{target_name} turned {action}.
|
||||
throttle: 5m
|
||||
on:
|
||||
- action
|
||||
- stale
|
||||
|
||||
rules:
|
||||
- name: top up from grid when low
|
||||
when: battery_soc <= 35
|
||||
for: 2m
|
||||
then: target.on
|
||||
|
||||
- name: stop charging when full enough
|
||||
when: battery_soc >= 85
|
||||
for: 2m
|
||||
then: target.off
|
||||
|
||||
# pv_surplus is solar minus everything drawing from the unit. Positive means
|
||||
# the sun is covering the load and the excess is charging the battery.
|
||||
#
|
||||
# The long dwell matters: a variable load such as a desktop PC will cross
|
||||
# zero constantly, and a short dwell would cycle the relay all afternoon.
|
||||
- name: solar is carrying the load, stay off the grid
|
||||
when: pv_surplus > 200 and battery_soc > 50
|
||||
for: 15m
|
||||
then: target.off
|
||||
|
||||
- name: solar cannot keep up, fall back to the grid
|
||||
when: pv_surplus < -200 and battery_soc <= 50
|
||||
for: 15m
|
||||
then: target.on
|
||||
|
||||
limits:
|
||||
min_seconds_between_actions: 60
|
||||
max_actions_per_hour: 20
|
||||
Reference in New Issue